T5250

T5250

The Product Features

  • High productivity – 2 full loads per hour
  • Low energy consumption for optimal efficiency
  • Large door opening for easy loading/unloading
  • Large selfcleaning lint screen for easy maintenance
  • Reversable door hanging for a convenient laundry flow
  • Easy access to vital parts from the top and rear for simple servicing
  • With Compass Pro® program control
    • Large display and one control knob for easy program selection
    • Language selection
    • Quick selection start and option buttons for frequently used drying programs and options
    • Drying program packages optimized for Economy, Care and Time and option buttons for selection of dryness
    • Service program for adjustment of parameters
    • USB connection
  • The coin version with Ecopower to avoid over drying of the garments and get a lower energy consumption

Key Benefits For T5250

Tailored to your needs
The range comes with a wide selection of option and accessories including customized user panels to meet the specific needs of your business.

User-friendly
Designed specifically to ensure safe and simple operation.

Economical
We provide optimised economy and high productivity. You can dry 2 loads of pure cotton fabric with 50 percent moisture content every hour. You can optimise your economy by using the Residual Moisture Control™ (RMC) that measures the actual moisture control.

Trouble-free operation
Our machines are designed for minimal maintenance requirements and are easy to service.

Specifications For T5250

Main Specification

Rated capacity, filling factor 1:18 kg/lb 13.9/30.7
Rated capacity, filling factor 1:22 kg/lb 11.4/25.1
Drum volume, litre 250
Drum volume, litre 250
Drum diameter, mm 760
Heating, electric kW 6/9/13.5
Heating, gas BTU/h (kW) 46000 (13.5)
Heating, steam at 800 kPa 25
Consumption data* 6 kW** 9 kW 13.5 kW Gas Steam
Total time full load, min 36 36 27 27 18
Energy consumption full load, kWh 3.9 5.5 5.8 6.2 13
Evaporation, g/min 111 160 214 211 326
Energy kWh/litre water evaporated, kWh/l 0.98 0.95 1.02 1.09 2.23

Dimensions

Height, mm 1770
Width, mm 790
(a) Depth el and gas, mm 958
(b) Depth steam, mm 1125

Other specifications

Sound pressure, level <70
Heat emission % of installed power 15